Sign In | Join Free | My himfr.com
Home > Piezo Ceramic Element >

Round Piezo Ceramic Element P4 / P8 With RoSH CE Certification

    Buy cheap Round Piezo Ceramic Element P4 / P8 With RoSH CE Certification from wholesalers
     
    Buy cheap Round Piezo Ceramic Element P4 / P8 With RoSH CE Certification from wholesalers
    • Buy cheap Round Piezo Ceramic Element P4 / P8 With RoSH CE Certification from wholesalers

    Round Piezo Ceramic Element P4 / P8 With RoSH CE Certification

    Ask Lasest Price
    Brand Name : CCWY
    Certification : RoSH
    Supply Ability : 1000PCS +per Month
    Delivery Time : 30 days
    • Product Details
    • Company Profile

    Round Piezo Ceramic Element P4 / P8 With RoSH CE Certification


    RoSH CE Certification Piezo Ceramic Round Shape P4 or P8 Element


    Piezoelectric ceramic materials are electromechanical transducers: They can convert mechanical energy into electrical energy and vice-versa. Piezoelectric ceramic material from us are used in sensors, actuators, gas ignition and in power transducers for high-power ultrasonic applications.


    Ultrasound is a kind of sound wave whose frequency is higher than 20000 Hz. It has good directionality and strong penetrating ability. It is easy to obtain more concentrated sound energy. It can be used in distance measurement, speed measurement, cleaning, welding and gravel. , sterilization and so on. There are many applications in medicine, military, industry, and agriculture. Ultrasound is named because its lower frequency limit is greater than the human hearing limit.
    Scientists refer to the number of vibrations per second as the frequency of the sound, and its unit is Hertz (Hz). The frequency of sound waves that our human ear can hear is 20Hz-20000Hz. Therefore, we call sound waves with a frequency higher than 20,000 Hz as "ultrasonic waves." Ultrasound frequencies commonly used for medical diagnosis are 1 MHz to 30 MHz.


    Dimension(mm)Capacity C (pF)

    Weak

    Field

    Dissipatio

    Tgδ (12v)

    Strong

    Field

    Dissip

    ationTg δ

    (400v)

    Radial

    Frequency
    Fr(KHz)

    Reso

    nance

    Impedance
    Zm (Ω )

    Thick FrequencyFt (KHz)Coupling Modulus Kr (%)Quality Factor Qm
    Φ10xΦ5x2240±10%≤0.5%≤1.0%153±5%≤151020≥45≥800
    Φ16xΦ8x4340±10%≤0.5%≤1.0%95.8±5%≤20512≥45≥800
    Φ25xΦ10x4935±10%≤0.5%≤1.0%65.5±5%≤15512≥45≥800
    Φ30xΦ10x51150±10%≤0.5%≤1.0%58.4±5%≤15410≥45≥800
    Φ32xΦ15x51080±10%≤0.5%≤1.0%49.2±5%≤15410≥45≥800
    Φ35xΦ15x51430±10%≤0.5%≤1.0%45.5±5%≤15410≥45≥800
    Φ38xΦ15x51750±10%≤0.5%≤1.0%43.4±5%≤15410≥46≥800
    Φ40xΦ15x51970±10%≤0.5%≤1.0%42.8±5%≤15410≥45≥800
    Φ42xΦ15x52200±10%≤0.5%≤1.0%40±5%≤15410≥45≥800
    Φ42xΦ17x52110±10%≤0.5%≤1.0%38.8±5%≤15410≥45≥800
    Φ45xΦ15x52580±10%≤0.5%≤1.0%38.1±5%≤15410≥46≥800
    Φ50xΦ17x53160±10%≤0.5%≤1.0%34.8±5%≤15410≥45≥800
    Φ50xΦ17x62430±10%≤0.5%≤1.0%34.8±5%≤15315≥45≥800
    Φ50x35800±10%≤0.5%≤1.0%46±5%≤10681≥50≥800


    FRQ

    PHYSICS ANSWERS

    1. Reason to the existence of piezoelectricity?

    The essential unit which is a rhomboid or cubic shaped cage made up of atoms exists in some atomic lattice structures. Inside the cell, the cage is responsible for holding single semi-mobile ion that has numerous quantum position states. By applying electric field or by distorting the cage (applied strain), the ions post state will consequently shift. The basis or transformation to internal electric field shifts from mechanical strain is provided by coupling between the cage and central ion.


    2. How can poling and depoling in piezoceramic materials? Be explained?

    The piezoceramics should undergo high electric field for a sometime for the alignment of randomly oriented micro-dipoles in their proper formulation since the chemical composition is not simply responsible for the piezoelectric property of ceramics. This is called “poling” due to alignment resulted from application of high voltage. a “dislodging stress” is exerted on the micro-dipoles due to the application of electric field in the opposite direction if tried. There is only temporary change in polarization if low level field are applied since it bounces back on removal. There is also partly degradation of the polarization along with partial loss of properties when medium fields are applied. Polarization in opposite direction will be resulted if high fields are applied.


    3. Is there a possibility of using piezoceramic actuators at cryogenic temperatures?

    The answer is yes. From down to zero degrees Kelvin, allpiezo actuators continue to function even though it may appear counter-intuitive. Since electric fields cannot be changed by temperature at all and the inter-atomic electric fields are the basis for the piezoelectric effect, the most common piezoceramics does decrease due to piezo coupling as temperature drops. Most importantly the motion of most materials drops to about one-seventh of that measured at room at liquid helium temperatures.


    PIEZO TECHNOLOGY ANSWERS

    1.What is the process of eliminating vibration through piezoceramics?

    The process of vibration cancellation can be achieved through attaching two piezoceramic sheets to the outer surface of the object. They should be close to the point (in a beam) where undesired bending needs to be controlled.The first sheet is used to measure the strain on the surface. The data from a strain sensor is put into a smart box. This gadget controls the power amplifier which consequently drives second sheet.As a result, the mechanically induced movement from second sheet produces vibrations into the structure, which counter the other vibrations.


    2.Is there a possibility of Piezo technology replacing magnetic technology anytime in the future?

    The possibility of Piezo technology replacing magnetic technology is not possible. Magnetic technology is based on force without physical contact. On the other hand, Piezo technology is purely derived from forces having direct contact from bodies.For instance, Piezo actuators have the capability of making all solenoids obsolete. However, they are heavier which is why it is highly improbably that magnetic technology will be forgotten because of Piezo technology.The main interest in Piezo actuators is because of the solenoids ability to work on less powe


    About US

    WHO WE ARE

    Our policy is to achieve customers' satisfaction both by providing them with high level product quality and services that meet or exceed their expectation. Our aim is to ensure that our clients continue to put their faith in us for many years to come.


    Packaging & Shipping

    Packaging Detail:

    Ultrasonic Piezoelectric ceramic cylinder Packing: Foam/

    plastic bag and carton/wodden box

    Delivery Detail:Within 30 Working Days

    Product Tags:

    piezoceramic materials

      

    piezo material

      
    Quality Round Piezo Ceramic Element P4 / P8 With RoSH CE Certification for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Beijing Cheng-cheng Weiye Ultrasonic Science & Technology Co.,Ltd
    *Subject:
    *Message:
    Characters Remaining: (0/3000)